유량 (Flow) ∙ Force
- 인장, 압축, load Cell
- 유량 (미량, 고압, liquid)
- 정적 토크, 동적 토크
- 전위차, RPM
Axial Turbine
Technical Data
Measuring range :
Accuracy :
Reproducibility :
Nominal pressure :
Process connection :
2~40L/min
±1%
±0.2%
PN10
G¾" external thread
Axial Turbine
Technical Data
Measuring range :
Accuracy :
Reproducibility :
Resolution :
Process connection :
4~160L/min
±5%
±0.5%
15ml/pulse
G1¼" external thread
Axial Turbine
Technical Data
Measuring range :
Operating range :
Reproducibility :
Maximum pressure :
Nominal pressure :
6.7~417L/min, 1.8~1,133L/min
up to +120˚C
±0.5%
250bar
PN10
Liquid
Technical Data
Measuring principle :
Measuring range :
Accuracy :
Pressure :
Reaction time (63%) :
Pressure pulsation
1~12L/min ... 10~200L/min
±1.5%
10bar
<1S
미량 (고압)
Technical Data
Measuring range :
Accuracy :
Reproducibility :
Pressure :
Maximum temperature :
0.1L/min, ...250L/min
±1%
±0.2%
up to 300 bar
up to +150˚C
Load Cell (인장·압축)
Technical Data
Measuring range :
Accuracy :
Nominal measuring path :
Operative range :
20N, 50N, 100N, 200N, 500N
1kN, 2kN, 5kN, 10kN, 20kN, 50kN
<±0.1%
<0.15mm
-10 to +70˚C
Load Cell (압축)
Technical Data
Measuring range :
Max. load limit :
Max. dynamic load :
Accuracy :
100N, 200N, 500N, 1kN, 2kN,
5kN, 10kN, 20kN, 50kN
150% of final value
70% of final value
<±0.5%
Rotating Torque
Technical Data
Measuring range :
Accuracy :
Output current :
Temperature cofficient :
Voltage UF :
1~5,000Nm
0.1% of final value
max. 100mA
<50ppm/˚C
5V, ±0.5V
전위차
Technical Data
Working length :
Resolution :
Vibrations :
Operating force (horizontal) :
Protection system :
25, 50, 75, 100, 150 mm
0.001mm
5 to 2,000Hz / Amax
≤0.30N
IP40
RPM
Technical Data
Measuring range :
Accuracy :
Resolution :
Bright-up pulse time :
Detection range :
8~30,000rpm
±0.02%
1rpm
>1ms
20~200mm